Specifications
| Brand | RITAR |
|---|---|
| Part number | FT12-125 |
| Voltage (V) | 12 |
| Capacity (C20) | 125 |
| Capacity (C10) | 125Ah (c10) |
| Technology | AGM |
| Length | 552.00 mm |
| Width | 110.00 mm |
| Height | 239.00 mm |
Resolvieron todas mis dudas
Recibí en plazo. Todo ok
Recomiendo la web por su trato al momento de elegir
Ritar FT12-125 12V 125Ah is a front-terminal telecom battery: designed for cabinets and racks where servicing is done from the front.

Designed for UPS, alarms, telecoms and emergency lighting, the Ritar FT12-125 from the FT range offers 125 Ah with AGM technology on permanent float charge. It measures 552 × 110 × 239 mm, the format sought by anyone replacing a 125 Ah battery in UPS, alarm and emergency systems.
With 125 Ah, the Ritar FT12-125 gives your UPS or emergency system the autonomy it needs. Replace all the batteries in the set at once. Check that it matches your current battery in dimensions, terminals and hold-down: this reference has a weight of 36 kg and M8 terminals.
It has external dimensions of 552 × 110 × 239 mm and weighs 36 kg. It uses M8 terminals, the system that anchors and connects it in the vehicle. For a direct replacement, the current battery tray must accept these dimensions and the same terminal layout; otherwise adapters will be needed or the hold-down will change.
With more than twenty years making sealed lead batteries, Ritar offers general-purpose, long-life, high-rate and front-terminal ranges for every stationary application. At baterias.com we work directly with the manufacturer or its official distributor: real stock, brand-new product and official warranty.
The FT12-125 is part of the Ritar FT range. Choosing the right reference within the series comes down to capacity, dimensions and terminals: technology and quality are common to the whole family.
In an AGM battery the electrolyte is absorbed in glass-fibre separators: there is no free liquid, it cannot spill and it can be mounted at an angle. That construction lowers internal resistance, speeds up recharging and multiplies cycle life compared with a conventional battery.
Replace all the batteries in the set at once and avoid environments continuously above 25 °C. Charge with a charger that has an AGM mode: it limits the voltage and protects the glass-fibre separators.
The Ritar FT12-125 comes with the manufacturer's official warranty against manufacturing defects. If it fails through a defect within the warranty period, we replace it at no cost to you.
Order before 6:00 pm with stock available and it leaves today: mainland Spain and Portugal receive it in 24-48 working hours, the islands and the rest of the EU in 3 to 5 days. You have 14 days to return it if it has not been installed, with free collection on the mainland, and shipment tracking by email.
Data sheet
Specific References
Resolvieron todas mis dudas
Recibí en plazo. Todo ok
Recomiendo la web por su trato al momento de elegir
Guide to replace a cyclic battery (12V 4-30Ah) for UPS, mobility scooter, alarm or backup device. Estimated time 10-15 minutes. Important: discharge residual voltage before handling.
Unplug the device (UPS, scooter, alarm) and leave it off for at least 30 seconds to discharge residual capacitor voltage. Work on an insulating surface.
Usually under the seat (mobility scooter/wheelchair), in the rear module of the UPS, or behind a side panel with screws. Check the device manual for unusual models.
With insulated gloves, remove the negative (−) cable first. Some UPS have protection fuses — note their position before removing.
Repeat with the positive cable (red, marked +). Important: never let a terminal touch metal of the car while the other is still connected.
Typical weight 1-15 kg depending on capacity. Many cyclic batteries are AGM/GEL — keep them upright. Do NOT invert the battery: even sealed, residue may exist.
Same orientation and type (AGM, GEL or flooded). Polarity must match the device, not a chassis (this is not a car). Make sure terminals do not touch metal parts of the compartment.
On cyclic devices the order is reversed compared to cars: positive (+) first, negative (−) afterwards. Tighten without forcing — the plastic terminal housing of cyclic batteries damages easily.
Cyclic batteries ship at 60-80%. Before first use, connect the device charger for 8-12 hours (or use an AGM/GEL smart charger if available). This avoids short cycles and extends lifespan.
Yes. The FT12-125 from Ritar uses AGM (Absorbent Glass Mat) technology: a sealed lead-acid battery where the electrolyte is absorbed in a glass-fibre mat. It withstands more charge/discharge cycles than a conventional one, handles heat better and is the required technology for devices with advanced Start-Stop and regenerative braking. Expected lifespan: 5-8 years under normal conditions.
In most devices it fits in 15-30 minutes with a 10 mm wrench; if the battery is under the seat or in the boot the time can double. See the step-by-step guide on this page. Quick summary: 1) switch off the engine and remove the key; 2) locate the original battery (engine bay, boot or under seat); 3) disconnect the negative (−) terminal first, then the positive (+); 4) loosen the hold-down clamp and remove the old battery; 5) fit the new one in the same orientation — match the polarity shown on the product sheet; 6) connect the positive (+) first, then the negative (−). On devices with Start-Stop or BMS, register the battery via OBD so the alternator applies the correct charging profile.
Expected lifespan of the Ritar FT12-125 is 5 to 8 years in mild-climate device use with Start-Stop. In cold regions it drops slightly due to cold-start stress; in very hot regions it also drops because of electrolyte evaporation. To extend its life: avoid deep discharges (headlights on with engine off), have the alternator checked yearly, and keep the battery clean and properly secured.
Dimensions (length × width × height) are 552×110×239 mm — also written as 552x110x239 mm — following the European DIN standard. Always measure the space in your device before buying: even one extra millimetre can prevent the hold-down clamp from closing. The height shown includes the terminals.
Directly interchangeable batteries (same dimensions, same polarity, same Ah and CCA) are the OEM equivalents from leading brands: Bosch, Tudor, Exide and, depending on the model, Banner or Yuasa. Exact equivalence depends on technology — an EFB cannot be replaced with a conventional battery in Start-Stop devices. See the "Equivalents" section to view recommended options at the same performance level.
Audited by Trustpilot, no filters, no edits. The top-rated battery store in Spain.
Trustpilot · verified, no filters
Official Varta distributor
Official Varta wholesale distributor. 100% genuine batteries, recently manufactured, best price and no middlemen.
World’s best-selling battery brand
+100,000 satisfied customers
More than 100,000 customers already trust baterias.com — and recommend us to their friends and family.
They trust us and recommend us
Choose trust, choose quality, choose baterias.com.